PosiTest 15
Fiber Position Measuring Device The PosiTest 15 measures the distance from the POF fiber end (inside of the ferrule) to the end of the ferrule. A typical tolerance range for MOST ferrules is 0,01 to 0,1 mm. This “recessed” fiber position is required so that the fiber ends do not get scratched during handling or mating.
Function
The PosiTest 15 is calibrated using a calibration pin. The operator then uses the PosiTest 15 to measure the fiber position inside of the ferrule with respect to the front end of the ferrule.
All measuring data can be visualized on a computer screen and saved using an Opto- RS232-interface-cable.
Special Features
- Versions for plug and socket type ferrules
- Design based on a digital micrometer with a resolution of 0.001 mm
- Constant spring-driven contact pressure eliminates operator variability
Technical Specifications
Attribute | Value |
Ferrule types | For SI/MOST plug and socket type ferrules |
Interfaces | Opto-RS232 |
Options | Must specify plug or socket version |
Power Supply | Coin cell battery 3V |
Net Weight | 2 kg |
Measurements (L x W x H) | 200 x 90 x 90 mm |
CE-Conformity | The PosiTest 15 fully complies with CE guidelines. |
Important Notice | We recommend that you send us completed cable assemblies and specifications for review. |